Liebherr 60 Bedienungsanleitung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
Freestanding/Semi Built In Models
Cabinet Opening Dimensions - 30" and 60" Models
The appliance can be integrated into the kitchen units. To
adapt the appliance to the height of the row of kitchen units, a
suitable top cupboard can be fitted above the appliance.
Unit Venting
DO NOT restrict the air flow. An air flow of at least 2" (50mm)
must be provided. The opening can either be directly over the
appliance or on the back of the cabinet on top of the unit (see
ventilation requirements).
The CS models can be installed in standard 24" deep cabinets.
You will only have to make sure that the door swing clearance
is enough. It is possible to push all CS models to the rear wall
of the cabinet without modification.
When installing the appliance next to a wall, a distance on the
hinge side of 1 27/64 inches (36 mm) minimum is required be-
tween the appliance and the wall to allow for the door handle
projection when the door is open.
Minimum Cabinet Opening Dimensions:
CS 1601, 1650
A. 29-7/8" (759 mm)
B. 23-3/16" (589 mm)
C. 85" (2159 mm)
D. 83-11/16" (2075 mm)*
SBS 32S0 (CS 1601 & CS 1650)
A. 59-1/2" (1511 mm)
B. 23-3/16" (589 mm)
C. 85" (2159 mm)
D. 83-11/16" (2075 mm)*
*Note:
The given cabinet opening height dimension includes 2" for top
air vent.
If you choose to place the vent above the cabinet or in a soffit,
you will need to adjust the height dimension accordingly.
CS 1601, CS 1650, SBS 32S0
5
Water supply area.
Do not install the
shut-off valve behind
the appliance.
Electric outlet location
Seitenansicht 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 20

Kommentare zu diesen Handbüchern

Keine Kommentare